1.
Haemophilia ; 22(5): 790-8, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27456473

RESUMO

INTRODUCTION: The prophylactic administration of clotting factor concentrate is currently the most effective strategy for the prevention of joint bleeding. As new agents with different mechanisms of action and administration schedules are developed, it will be important to study them in relevant preclinical models. AIM: The aim of this study was the standardization of a mouse haemarthrosis model in a haemophilia mouse and the development and validation of a comprehensive bleeding assessment system, the Bleeding Severity Score (BSS). METHODS AND RESULTS: Four outcome measurements were assessed, two of which, the extra-articular bleeding score and intra-articular bleeding score, were determined to be the most reliable and were summarized into a BSS which was validated using a mouse haemarthrosis variability model. CONCLUSION: Using this model, the haemostatic effect of prospective drugs can be assessed in a clinically relevant joint bleeding model and will significantly increase the value of preclinical studies.


Assuntos
Fator VIII/genética , Hemartrose/patologia , Animais , Testes de Coagulação Sanguínea , Coagulantes/uso terapêutico , Modelos Animais de Doenças , Fator VIII/análise , Fator VIII/uso terapêutico , Hemofilia A/tratamento farmacológico , Hemofilia A/patologia , Humanos , Articulações/fisiologia , Camundongos , Camundongos Knockout , Índice de Gravidade de Doença
2.
Haemophilia ; 21(1): 58-63, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25459309

RESUMO

Prophylaxis prevents joint and other bleeding episodes in patients with haemophilia A. Development of new factor concentrates with longer circulating half-lives may encourage patients to start, continue or resume prophylaxis. The aim of this study was to compare the pharmacodynamic effect of a PEGylated full-length recombinant factor VIII (rFVIII) concentrate with that of an unmodified rFVIII concentrate with respect to the duration of prophylactic efficacy in a murine model of haemophilic joint bleeding. Mice were pretreated with BAX 855 or unmodified rFVIII at specified times before right knee puncture to induce haemarthrosis; left knee joints served as controls. Joint bleeding was evaluated using a combination of visual and histological assessments. Administration of a single dose of unmodified rFVIII before joint puncture prevented haemarthrosis in mice up to 24 h, whereas pretreatment with BAX 855 protected the joint from bleeding up to 48 h. This pharmacodynamic study showed prolonged efficacy of BAX 855 compared to ADVATE in a haemophilia A mouse joint bleeding model. This finding supports the possibility of using BAX 855 to increase FVIII trough levels and/or extend the dosing interval in patients with haemophilia A on prophylaxis, which may potentially improve prophylactic efficacy and long-term adherence.


Assuntos
Fator VIII/administração & dosagem , Hemofilia A/tratamento farmacológico , Animais , Modelos Animais de Doenças , Hemorragia/prevenção & controle , Humanos , Camundongos , Proteínas Recombinantes/administração & dosagem
3.
Haemophilia ; 20(1): 9-14, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23855877

RESUMO

The phenotypic variability in haemophilia is well documented; however, the biological basis beyond factor VIII and IX activities to explain the differing clinical pictures of the disease remains unclear. It has therefore been of interest to explore other modulators of the disease's variability. Furthermore, a scoring system that reflects the multiple facets of haemophilia symptoms would be useful to compare patients via a comprehensive assessment tool. To this end, Schulman et al., created a measure known as the Haemophilia Severity Score (HSS) as one way to compare phenotypic severity. The aim of this study was to document the differing symptomatology of haemophilia patients using the HSS. Clinical data for 178 haemophilia patients without inhibitors were reviewed and annual incidence of haemarthrosis, orthopaedic joint scores and annual factor usage calculated. Each parameter was then entered into the formula to create the HSS for haemophilia A and B patients with mild, moderate and severe factor deficiencies. Variability in the HSS for patients with the same baseline level of factor was observed for all three deficiency levels and both haemophilia types. In addition, we found that moderate and severe haemophilic B patients tended to have more morbidity based on the above calculations than the haemophilic A counterparts. The HSS is a comprehensive tool that allows for easy numerical comparison of haemophilic patients and elucidates the variable clinical presentation of the disease. The HSS could be used to stratify patients via other possible modulators of haemophilia and discover other aetiologies of the disease.


Assuntos
Hemofilia A/diagnóstico , Hemofilia B/diagnóstico , Medicina de Precisão , Adolescente , Testes de Coagulação Sanguínea , Criança , Pré-Escolar , Feminino , Hemofilia A/complicações , Hemofilia A/terapia , Hemofilia B/complicações , Hemofilia B/terapia , Humanos , Lactente , Masculino , Fenótipo , Índice de Gravidade de Doença
4.
Haemophilia ; 18(3): 310-8, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22044636

RESUMO

Haemophilia has been recognized as the most severe among the inherited disorders of blood coagulation since the beginning of the first millennium. Joint damage is the hallmark of the disease. Despite its frequency and severity, the pathobiology of blood-induced joint disease remains obscure. Although bleeding into the joint is the ultimate provocation, the stimulus within the blood inciting the process and the mechanisms by which bleeding into a joint results in synovial inflammation (synovitis) and cartilage and bone destruction (arthropathy) is unknown. Clues from careful observation of patient material, supplemented with data from animal models of joint disease provide some clues as to the pathogenesis of the process. Among the questions that remain to be answered are the following: (i) What underlies the phenotypic variability in bleeding patterns of patients with severe disease and the development of arthropathy in some but not all patients with joint bleeding? (ii) What is the molecular basis underlying the variability? (iii) Are there strategies that can be developed to counter the deleterious effects of joint bleeding and prevent blood-induced joint disease? Understanding the key elements, genetic and/or environmental, that are necessary for the development of synovitis and arthropathy may lead to rational design of therapy for the targeted prevention and treatment of blood-induced joint disease.


Assuntos
Hemofilia A/complicações , Artropatias/etiologia , Animais , Anticoagulantes/uso terapêutico , Fator VIII/uso terapêutico , Hemartrose/etiologia , Hemartrose/prevenção & controle , Hemofilia A/tratamento farmacológico , Humanos , Artropatias/fisiopatologia , Camundongos , Modelos Moleculares , Fenótipo , Sinovite/etiologia , Sinovite/prevenção & controle
5.
Haemophilia ; 14(4): 804-9, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18422608

RESUMO

Recurrent haemarthrosis results in chronic synovitis and destructive arthropathy. The long-term effect of a single haemorrhage is not known. To investigate the histopathological changes following a single, but major joint haemorrhage, an animal model of massive haemarthrosis without mechanical trauma was developed and is described in this manuscript. The knee joint capsule of mice deficient in coagulation factor VIII or IX and non-haemophilic wild type mice was punctured to induce a one time, but massive haemorrhage. The single joint puncture resulted in acute haemarthrosis in both types of haemophilic mice but not in wild type mice. Subsequent to injury, the changes in the knee joints were analysed using gross, histological and radiographic assessments and compared with the uninjured knee. In addition, a novel imaging modality, micro-computed tomography, was used to document the structural damage to the joint. Our results indicate that the long-term changes classically observed in patients with advanced haemophilic arthropathy are evident following a single massive haemarthrosis. This model will allow a thorough investigation of the pathobiology of blood-induced joint disease and will be useful to test the efficacy of innovative therapeutic strategies to prevent haemophilic synovitis and arthropathy.


Assuntos
Hemartrose/etiologia , Hemofilia A/complicações , Animais , Cartilagem Articular/metabolismo , Modelos Animais de Doenças , Fator VIII/uso terapêutico , Hemartrose/diagnóstico por imagem , Hemartrose/patologia , Hemartrose/prevenção & controle , Hemofilia A/tratamento farmacológico , Camundongos , Camundongos Knockout , Proteoglicanas/metabolismo , Proteínas Recombinantes/uso terapêutico , Sinovite/diagnóstico por imagem , Sinovite/etiologia , Sinovite/patologia , Sinovite/prevenção & controle , Microtomografia por Raio-X/métodos
6.
Haemophilia ; 14(1): 119-26, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18184259

RESUMO

Haemophilia is a congenital disorder that commonly results in musculoskeletal bleeding and orthopaedic complications. After an acute joint haemorrhage, an increase in intra-articular pressure and inflammation cause pain, swelling and limited motion. Blood in the joint space provokes a proliferative disorder known as haemophilic synovitis. Overgrowth of the synovial membrane causes mechanical dysfunction. Eventually, there is destruction of the articular surface and underlying bone. The aim of this project was to test the hypothesis that a minimum number of haemarthroses negatively impacts on joint function and that this would be reflected by decreased physical performance of experimental animals. Mice deficient in factor VIII coagulant activity were trained to ambulate on a rotating rod then injured three times at weekly intervals. Their ability to walk was then compared to a group of uninjured mice. Cohorts of mice were killed after 1, 2 or 3 months and the knee joints examined by gross and histological methods. The results supported the following conclusions: (i) haemophilic mice can be trained to ambulate on a rotating rod; (ii) acute hemarthrosis temporarily impairs their ability to ambulate and (iii) following recovery from acute injury, mice developing synovitis demonstrated inferior physical ability compared to mice not developing synovitis. This is the first description of a quantitative assay to monitor joint function in experimental animals and should be useful to evaluate the efficacy of new therapies developed to prevent and treat bleeding and to test strategies to counter the devastating effects of synovitis.


Assuntos
Hemartrose/fisiopatologia , Hemofilia A/complicações , Sinovite/fisiopatologia , Animais , Modelos Animais de Doenças , Articulações/lesões , Camundongos , Movimento , Amplitude de Movimento Articular , Fatores Sexuais , Taxa de Sobrevida , Sinovite/etiologia
7.
Atherosclerosis ; 152(1): 107-15, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10996345

RESUMO

In the present study we try to define the optimal conditions for preparation of copper-oxidized low-density lipoprotein (oxLDL) to be used for the assay of oxLDL antibodies by enzyme immunoassay (EIA). Oxidation of LDL was monitored by measuring the formation of conjugated dienes at 234 nm and the generation of fluorescent products with emission at 430 nm when excitation is performed at 360 nm. The generation of immunogenic epitopes was evaluated by testing the reactivity of aliquots collected at different times during the oxidation process with human sera with high oxLDL antibody levels and with a purified human oxLDL antibody. The values of fluorescence emission at 430 nm correlated best with reactivity with oxLDL antibodies; strong reactivity was usually associated with values greater than 1.1 U. The time needed for fluorescence emission to reach maximum levels varied between 6 and 14 h for most LDL, but it was considerably longer in a few LDL preparations. The maximal reactivity of oxLDL with oxLDL antibodies was observed when the LDL oxidation reaction was stopped 4 or more hours after the fluorescence readings reached their peak. At this stage of the oxidation reaction, apolipoprotein B fragmentation and aggregation were observed as shown by Western blot analysis. The CV for 13 EIA runs of two reference oxLDL antibodies reacting with four different pools of standardized oxLDL prepared according to the stated guidelines was 14.5 and 3.9%, confirming the reproducibility of our oxidation conditions.


Assuntos
Arteriosclerose/imunologia , Autoanticorpos/sangue , Lipoproteínas LDL/imunologia , Lipoproteínas LDL/metabolismo , Complexo Antígeno-Anticorpo/análise , Cobre/metabolismo , Humanos , Técnicas Imunoenzimáticas , Oxirredução , Sensibilidade e Especificidade
8.
Clin Diagn Lab Immunol ; 5(6): 817-22, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9801341

RESUMO

As part of our ongoing effort to develop a standardized competitive enzyme immunoassay for human autoantibodies to oxidized low-density lipoprotein (oxLDL), we have generated a reference human antibody standard and revised some of the conditions of the assay. The preparation of the standard involved purification of human anti-oxLDL antibodies by affinity chromatography using immobilized oxLDL. The total concentration of antibody in this purified human oxLDL antibody was established by adding the concentrations of immunoglobulin G (IgG), IgA, and IgM determined in the standard by radial immunodiffusion. The isolated antibody was used to calibrate a whole human serum standard, which was used to calibrate the assays to detect antibody in serum samples. We also revisited the general conditions for performance of our competitive assay. We determined that 1/20 was the ideal dilution for performing the absorption step, and that 1/20 and 1/40 were optimal dilutions to assay oxLDL antibody in unknown serum samples. We also established that the optimal concentration of oxLDL for absorption of free antibody in serum samples was 200 microgram of oxLDL/ml; no significant decrease in the reactivity of samples with immobilized oxLDL was observed when higher concentrations of oxLDL were used for absorption. The minimum detection level of the assay is 0.65 mg/liter. Because serum samples are diluted 1/20 and 1/40 for the assay, the minimal concentration of antibody detectable in serum is 20-fold higher, i.e., 13 mg/liter. The intraassay coefficient of variation calculated from seven determinations of three samples containing antibody concentrations of 240, 340, and 920 mg/liter ranged from 8 to 6.1%. The interassay coefficients of variation for sera with antibody levels of 100 to 594 mg/liter varied from 9.2 to 7.0%, and for isolated antibodies with concentrations of 52 to 111 mg/liter, the coefficients varied from 5.8 to 3.9%.


Assuntos
Autoanticorpos/sangue , Técnicas Imunoenzimáticas/normas , Lipoproteínas LDL/imunologia , Autoanticorpos/isolamento & purificação , Calibragem , Humanos , Lipoproteínas LDL/isolamento & purificação , Oxirredução , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade